600W single output PFC AC/DC switching power supply
¨ª Universal AC input/ Full range ¨ª Built-in active PFC function,PF>0.96 ¨ª Using ZVS technology to reduce power dissipation ¨ª Built in Fan speed control and over temp.protection ¨ª Built in AC inrush current limiting circuit(<20A) ¨ª Build in constant current limiting circuit ¨ª Built in Remote Sense Function ¨ª Build in DC OK signal ¨ª Wide operating ambient temperature (-20¡É~70¡É) ¨ª 1 U low profile,42.5mm ¨ª 3 years warranty
MODEL |
PDF-600-12 PDF-320-5 |
PDF-600-24 PDF-320-12 |
PDF-600-36 PDF-320-32 |
PDF-600-48 PDF-320-48 |
OUTPUT |
DC Output |
12V 5.0V |
24V 12V |
36V 32V |
48V 48V |
Rated Current |
50A 60A |
25A 25A |
17.5A 10A |
12.25A 6.7A |
Current Range Note 1 |
0~50A 0~60A |
0~25A 0~25A |
0~17.5A 0~10A |
0~12.25A 0~6.7A |
Ripple and Noise Note 2 |
0-70¡É |
120mV 150mV |
150mV 150mV |
150mV 200mV |
200mV 240mV |
-30¡É |
180mV 180mV |
150mV 150mV |
150mV 200mV |
200mV 240mV |
Voltage ADJ. Range |
¡¾10% of rated output voltage |
Voltage Accuracy |
¡¾2.0% ¡¾2.0% |
¡¾2.0% ¡¾1.0% |
¡¾2.0% ¡¾1.0% |
¡¾2.0% ¡¾1.0% |
Line Regulation |
¡¾0.5% ¡¾0.5% |
¡¾0.5% ¡¾0.3% |
¡¾0.5% ¡¾0.2% |
¡¾0.2% ¡¾0.2% |
Load Regulation |
¡¾1.0% ¡¾1.0% |
¡¾1.0% ¡¾0.5% |
¡¾1.0% ¡¾0.5% |
¡¾1.0% ¡¾0.5% |
Set-up Time |
£¼1.5S (230Vac input, Full load), £¼3S (115Vac input, Full load) |
Hold up Time |
£¾16mS/ (230Vac input, Full load) |
Temperature Coefficient |
¡¾0.05%/¡É |
Overshoot and Undershoot |
<5.0% |
INPUT |
Voltage Range |
90Vac~264Vac,127Vdc~370Vdc |
Frequency Range |
47Hz--63Hz |
Power Factor(Typical) |
PF£¾0.98/115VAC PF£¾0.96/230VAC |
Efficiency ( Typical) |
88% 79% |
89% 86% |
90% 87% |
90% 88% |
AC Current (max.) |
<7A |
Inrush Current (Typical) |
<20A@230Vac Cold start |
Leakage Current |
Input—output: ¡Â0.1mA Input—PG: ¡Â0.75mA |
PROTECTION |
Over Load |
110%~135% of rated output current, constant current |
Over Temperture |
105¡É+5¡É(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 75¡É |
Over Voltage |
110%~150% of rated voltage; constant voltage |
Short Circuit |
Long-term mode, constant current, auto recovery |
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-30¡É~70¡É; 20%~90%RH No condensing (refer to derating curve) |
Storage Temp. & Hum. |
-40¡É~85¡É; 10%~95%RH No condensing |
SAFETY &EMC (Note 3) |
Safety Standards |
IEC60950/ UL60950 /; EN60950-1£º2006 |
Withstand Voltage |
Primary-Secondary:3.0KVac; ¡Â10mA .Primary-PG:1.5KVac; ¡Â10mA. Secondary-PG:0.5KVac;¡Â10mA. |
Isolation Resistance |
¡Ã100M ohms |
EMI Conduction&Radiation |
Compliance to EN55022(CISPR22)ClassB |
Harmonic Current |
Compliance to EN61000-3-2,17625.1-2003 |
EMS Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA |
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25¡É, Full load) |
Dimension (L*W*H) |
218¡¿116.5¡¿42.5mm |
Packing |
6PCS/CTN, 8.7KGS, 0.04CBM |
Cooling method |
Fored air cooling(Built-in fan) |
NOTE |
- All parameters NOT specially mentioned are measured at rated input, rated load and 25¡É of ambient temperature.
- Measured at 20MHz of bandwidth by using a 12¡± twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives |
|