ÆÃŬ¹ßÀü¼Ò´Â Àü±âº¯È¯ÀåÄ¡ °³¹ß »ý»ê Àü¹®±â¾÷ ÀÔ´Ï´Ù.
 
·Î±×ÀΠȸ¿ø°¡ÀÔ

¹®ÀÇÀüÈ­ : 1544-5440, 02-2068-1322 Æѽº : 02-2068-1323 ÀºÇàÁ¤º¸ : ±â¾÷ÀºÇà 147-062537-01-010, ±â¾÷ÀºÇà 632-008864-01-014 ÆÃŬ¹ßÀü¼Ò
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
SMPS PDF-600 [600W]
Á¦Á¶È¸»ç : powerld
ÆǸŰ¡°Ý : 150,000¿ø
ºÎ°¡¼¼º°µµ
¼ö·® EA
 
   

600W single output PFC AC/DC switching power supply

¨ª Universal AC input/ Full range
¨ª Built-in active PFC function,PF>0.96
¨ª Using ZVS technology to reduce power dissipation
¨ª Built in Fan speed control and over temp.protection
¨ª Built in AC inrush current limiting circuit(<20A)
¨ª Build in constant current limiting circuit
¨ª Built in Remote Sense Function
¨ª Build in DC OK signal
¨ª Wide operating ambient temperature (-20¡É~70¡É)
¨ª 1 U low profile,42.5mm
¨ª 3 years warranty


MODEL

PDF-600-12
PDF-320-5

PDF-600-24
PDF-320-12

PDF-600-36
PDF-320-32

PDF-600-48
PDF-320-48

OUTPUT

DC Output

12V
5.0V

24V
12V

36V
32V

48V
48V

Rated Current

50A
60A

25A
25A

17.5A
10A

12.25A
6.7A

Current Range Note 1

0~50A
0~60A

0~25A
0~25A

0~17.5A
0~10A

0~12.25A
0~6.7A

Ripple and Noise
Note 2

0-70¡É

120mV
150mV

150mV
150mV

150mV
200mV

200mV
240mV

-30¡É

180mV
180mV

150mV
150mV

150mV
200mV

200mV
240mV

Voltage ADJ. Range

¡¾10% of rated output voltage

Voltage Accuracy

¡¾2.0%
¡¾2.0%

¡¾2.0%
¡¾1.0%

¡¾2.0%
¡¾1.0%

¡¾2.0%
¡¾1.0%

Line Regulation

¡¾0.5%
¡¾0.5%

¡¾0.5%
¡¾0.3%

¡¾0.5%
¡¾0.2%

¡¾0.2%
¡¾0.2%

Load Regulation

¡¾1.0%
¡¾1.0%

¡¾1.0%
¡¾0.5%

¡¾1.0%
¡¾0.5%

¡¾1.0%
¡¾0.5%

Set-up Time

£¼1.5S (230Vac input, Full load), £¼3S (115Vac input, Full load)

Hold up Time

£¾16mS/ (230Vac input, Full load)

Temperature Coefficient

¡¾0.05%/¡É

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range

90Vac~264Vac,127Vdc~370Vdc

Frequency Range

47Hz--63Hz

Power Factor(Typical)

PF£¾0.98/115VAC PF£¾0.96/230VAC

Efficiency ( Typical)

88%
79%

89%
86%

90%
87%

90%
88%

AC Current (max.)

<7A

Inrush Current (Typical)

<20A@230Vac Cold start

Leakage Current

Input—output: ¡Â0.1mA Input—PG: ¡Â0.75mA

PROTECTION

Over Load

110%~135% of rated output current, constant current

Over Temperture

105¡É+5¡É(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 75¡É

Over Voltage

110%~150% of rated voltage; constant voltage

Short Circuit

Long-term mode, constant current, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-30¡É~70¡É; 20%~90%RH No condensing (refer to derating curve)

Storage Temp. & Hum.

-40¡É~85¡É; 10%~95%RH No condensing

SAFETY &EMC
(Note 3)

Safety Standards

IEC60950/ UL60950 /; EN60950-1£º2006

Withstand Voltage

Primary-Secondary:3.0KVac; ¡Â10mA .Primary-PG:1.5KVac; ¡Â10mA. Secondary-PG:0.5KVac;¡Â10mA.

Isolation Resistance

¡Ã100M ohms

EMI Conduction&Radiation

Compliance to EN55022(CISPR22)ClassB

Harmonic Current

Compliance to EN61000-3-2,17625.1-2003

EMS Immunity

Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,light industry level,criteriaA

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25¡É, Full load)

Dimension (L*W*H)

218¡¿116.5¡¿42.5mm

Packing

6PCS/CTN, 8.7KGS, 0.04CBM

Cooling method

Fored air cooling(Built-in fan)

NOTE

  1. All parameters NOT specially mentioned are measured at rated input, rated load and 25¡É of ambient temperature.
  2. Measured at 20MHz of bandwidth by using a 12¡± twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives

»óÈ£: ÆÃŬ¹ßÀü¼Ò ´ëÇ¥: È«¼ºÁø »ç¾÷ÀÚµî·Ï¹øÈ£: 105-05-38107 105-05-38107 Åë½ÅÆǸž÷¹øÈ£: 2012-¼­¿ï¿µµîÆ÷-0356
ÁÖ¼Ò: ¼­¿ï½Ã ¿µµîÆ÷±¸ ¾çÆò·Î21 °¡±æ 19, Bµ¿ 105È£.  E-mail : itinno@naver.com ±â¼ú¹®ÀÇ eng@twinklepower.co.kr 
°í°´»ó´ã: 1544-5440,02-2068-1322 Æѽº02-2068-1323, 02-2638-7033 °³ÀÎÁ¤º¸ º¸È£ Ã¥ÀÓÀÚ: È«¼ºÁø E-mail Copyright¨Ï ÆÃŬ ¹ßÀü¼Ò all rights reserved